AW-11144982321

Load table for calculations - for engineers and soil consultants

Types of ground screws - and foundation capabilities

Data table: types of screws according to diameter/length and carrying capacity.

Pull/load test

Despite the theoretical data regarding the use load capacity of the screws (according to the tables and soil data), it is recommended to perform a capacity test on site, easily and quickly - in order to give the planner the capacity data of the screws - in the area cell specific to the project. The test is usually done by the testing facility the ability of the screw to resist pulling out, by a hydraulic lever and a digital weight connected to the installed screw. The figure we get is divided in half, just to be safe. For example: a screw whose pull-out resistance is 2,200 kg, will be recommended by us for a load of up to 1,100 kg (approx. 1 ton). The test is super accurate, and relevant to the area of ​​land where it was performed. In large areas, I perform a number of tests in several areas - in order to make the findings accurate.

Israeli standard 918

Standard 918: Hot-dip zinc coating on steel products and iron casting products. The standard applies to hot-dip zinc plating. Our ground screws and the related products are manufactured subject to the European and American standards, and are also sent to laboratory tests in Israel, to obtain the Israeli standard 918, at Xenon Laboratories Ltd. You can see in the attached reports that the galvanization levels of the screws are more than double the standard's requirements.